ADJUSTMENT TO DIFFERENT TYPES OF GAS
This operation must be performed by a qualied technician.
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction.
• ThegasnozzlesmustbechangedbyAfterSalesServiceoraqualiedtechnician.
• NozzlesnotsuppliedwiththeappliancemustbeorderedfromAfterSalesService.
• Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difculty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap
if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
• Remove grids (A).
• Extractburners(B).
• Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to
be replaced.
• Replace it with the injector suitable for the new type of gas.
• Re-assemble the injector in (D).
• If you have a multiple crown burner use side spanner to replace the injector (E).
Beforeinstallingthehob,remembertoafxthegascalibrationplatesuppliedwiththeinjectorsin
suchawaythatitcoverstheexistinginformationrelatingtogascalibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
• tightenscrewtoreducetheameheight(-);
• loosenscrewtoincreasetheameheight(+)
Theadjustmentmustbeperformedwiththetapinminimumgassettingposition(smallame) .
• The primary air of the burners does not need to be adjusted.
• Atthisstage,lightuptheburnersandturntheknobsfrommaxposition to minimum position tocheckamestability.
Uponcompletionofadjustment,resealusingsealingwaxoranequivalentmaterial.
REFERENCE TO LOCAL REGULATIONS
Theinstallationandmaintenanceoftheappliancemustbecarriedoutbyaqualiedskilledtechnicianinaccordancewiththeregulationsinforce,andinparticular:
• Decree of 2 August 1977
TechnicalandSafetyRulesapplicabletofuelgasandliqueedhydrocarboninstallationslocatedwithinresidentialbuildingsandoutbuildings.
• Standard DTU P 45 - 204
Gasinstallations(formerlyDTUno.61-1-GasinstallationsApril1982+supplementno.1ofJuly1984).
• Departmental Health Regulations
For appliances connected to the mains electricity supply.
• Standard NF C 15-100
Low-voltageelectricalinstallations-Standards.
REFERENCE TO LOCAL REGULATIONS
Theapplianceissuppliedwitha1/2”threadedconicalendtobeconnectedtothegassupply(accordingtoISOregulationsISO 7/1 RP 1/2). The connection must be
effected in accordance with standard NBN D 51-003usingrigidpipingorinaccordancewithspecicationssheetA.R.G.B./03usingexibletubing.Theappliancemust
be installed complete with an AGB-approved stop valve.
AFTER-SALES SERVICE
Before calling the After-Sales Service, make sure you can give the following information:
- type of fault or problem;
- exactmodel(writtenonthelabelafxedtotheinstruction/warranty);