INJECTORS TABLE
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
.xam.tar.nimWk
NATURAL GAS
(Methane) G20
Rapid 128B 3.00 286 l/h0.60
16 20 25Semi-rapid 95 1.65 157 l/h0.35
Auxiliary78A 1.00 95 l/h0.30
NATURAL GAS
G2.350
Rapid 179A 3.00 397 l/h0.60
10 13 16Semi-rapid 129A 1.65 218 l/h0.35
Auxiliary104 1.00 132 l/h0.30
NATURAL GAS
G27
Rapid 1433.00348 l/h0.60
16 20 23Semi-rapid 106A 1.65 192 l/h0.35
Auxiliary851.00116 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid 88 3.00 218 g/h0.70
25 37 45Semi-rapid 62 1.65 120 g/h0.45
Auxiliary471.00 73 g/h0.35
Type of gas used Model
conguration
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar1 R - 2 SR - 1 AUX7.30695 l/
.52
G2.350 13 mbar 1 R - 2 SR - 1 AUX7.30965 l/
.85
G27 20 mbar1 R - 2 SR - 1 AUX7.30848 l/
.90
G30/G31 37 mbar 1 R - 2 SR - 1 AUX7.30531 l/
0.94
TRIC SUPPLY: 220-240 V ~ 50/60 Hz
WOK ADAPTER (not included,this accessory can be purchased separately from the After-sales Service)