DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
max. 492
510
560
590
min. 70
max.R 8
max.R 6,5
min. 480
42
750 min.
50 min.
100
B
B
A
NOTE: if the distance “A” between the wall cabinets is between 600 mm
and 730 mm, the height “B” must be a minimum of 530 mm.
If the distance “A” between the wall cabinets is greater than the width of
the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
INJECTORS TABLE
+3H2II YROGETAC
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
2 Ring 136B 3.50 333 l/h2.302.20
17 20 25Semi-rapid 97A1.75167 l/h0.450.35
Auxiliary78A 1.00 95 l/h0.400.30
NATURAL GAS
(Methane) G25
2 Ring 136B 3.50 388 l/h2.20
20 25 30Semi-rapid 97A1.75194 l/h0.35
Auxiliary78A 1.00 111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
2 Ring 93P 3.50 254 g/h 1.90
20 28-30 35Semi-rapid 66A1.75127 g/h0.35
Auxiliary501.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
2 Ring 93P 3.50 250 g/h 1.90
25 37 45Semi-rapid 66A1.75125 g/h0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model
conguration
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 2C - 2 SR - 1 AUX8.00762 l/
h9
.52
G25 25 mbar 2C - 2 SR - 1 AUX8.00887 l/
h8
.187
G30 28-30 mbar2C - 2 SR - 1 AUX8.00581 g/
h3
0.94
G31 37 mbar 2C - 2 SR - 1 AUX8.00571 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz