DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
max. 492
510
560
590
min. 70
max.R 8
max.R 6,5
min. 480
42
750 min.
50 min.
100
B
B
A
NOTE: if the distance “A” between the wall cabinets is between 600 mm
and 730 mm, the height “B” must be a minimum of 530 mm.
If the distance “A” between the wall cabinets is greater than the width of
the cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
INJECTORS TABLE
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
.xam.tar.nimRFEBWk
NATURAL GAS
(Methane) G20
2 Ring 136B 3.50 333 l/h2.302.20
17 20 25Semi-rapid 97A1.75167 l/h0.450.35
Auxiliary78A 1.00 95 l/h0.400.30
NATURAL GAS
(Methane) G25
2 Ring 136B 3.50 388 l/h2.20
20 25 30Semi-rapid 97A1.75194 l/h0.35
Auxiliary78A 1.00 111 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
2 Ring 93P 3.50 254 g/h 1.90
20 28-30 35Semi-rapid 66A1.75127 g/h0.35
Auxiliary501.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
2 Ring 93P 3.50 250 g/h 1.90
25 37 45Semi-rapid 66A1.75125 g/h0.35
Auxiliary501.00 71 g/h0.30
Type of gas used Model
conguration
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 2C - 2 SR - 1 AUX8.00762 l/
.52
G25 25 mbar 2C - 2 SR - 1 AUX8.00887 l/
.187
G30 28-30 mbar2C - 2 SR - 1 AUX8.00581 g/
0.94
G31 37 mbar 2C - 2 SR - 1 AUX8.00571 g/h 23.80
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz