PRATICAL ADVICE FOR USING THE BURNERS
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting.
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
• The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain lit,
wait at least one minute before trying to light it again.
NOTE: should particular local conditions of the delivered gas make the ignition of burner difficult, it is advisable to repeat
the operation with the knob turned to small flame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this
case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
This hob has burners of different diameters. For better burner performance,
please stick to the following rules:
- Use pots and pans with bottoms the same width as that of the burners or
slightly larger (see table on the right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and keep the pot
covered.
- Make sure pots on the grates do not protrude beyond the edge of the hob
- In the case of pans with convex bottoms (WOK), use the support grille
provided, which should be positioned only on the double crown burner.
IMPORTANT: improper use of the grids can result in damage to the hob: do
not position the grids upside down or slide them across the hob.
Do not use:
- Cast iron griddles, ollar stones, terracotta pots and pans.
- Heat diffusers such as metal mesh, or any other types.
- Two burners simultaneously for one receptacle (e.g. fish kettle).
Burner Pot Ø
Double crown (Wok) From 24 to 26 cm
Semi-rapid From 16 to 22 cm
Auxiliary From 8 to 14 cm
HOW TO USE THE HOB
WARNING
Do not let the burner flame extend beyond the edge of the pan.
NOTE: if a hood is installed above the hob, refer to the hood assembly instructions for the correct distance to be respected.
770 mm
751 mm
350 mm
331 mm
Min. 60 mm
Max. 218 mm
R = Min. 6 mm
Max. 8 mm
41 mm
6 mm
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of burner Injector
marking
Rated thermal
flow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
kW BE FR min. rat. max.
NATURAL GAS
(Methane) G20
Double crown 140 3.50 333 l/h
1.55 1.55
17 20 25Semi-rapid 97 1.65 157 l/h
0.35 0.35
Auxiliary 74 B 1.00 95 l/h
0.40 0.30
NATURAL GAS
(Methane) G25
Double crown 140 3.50 388 l/h
1.55
20 25 30Semi-rapid 97 1.65 183 l/h
0.35
Auxiliary 74 B 1.00 111 l/h
0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Double crown 93 3.50 254 g/h
1.55
20 28-30 35Semi-rapid 65 1.65 120 g/h
0.35
Auxiliary 50 1.00 73 g/h
0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Double crown 93 3.50 250 g/h
1.55
25 37 45Semi-rapid 65 1.65 118 g/h
0.35
Auxiliary 50 1.00 71 g/h
0.30
Type of gas used Model
configuration
Rated thermal
flow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar 3 burners 6.15 585 l/h 9.52
G25 25 mbar 3 burners 6.15 682 l/h 8.187
G30 28-30 mbar 3 burners 6.15 447 g/h 30.94
G31 37 mbar 3 burners 6.15 439 g/h 23.80
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Min. 5 cm
Min.
10 cm
Min. 40 cm
Min. 40 cm
Min. 75 cm
Min. 3,8 cm
Max. 6 cm