INJECTORS TABLE
Type of gas usedType of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
II2H3+
IT - ES - GR - PT
- AE - MA - TN -
DZ
NATURAL GAS
(Methane) G20
2 Ring
Rapid
Semi-rapid
Auxiliary
168
125A
97A
78A
4.80
3.00
1.75
1.00
457 l/h
586 l/h
167 l/h
95 l/h
2.20
0.60
0.35
0.30
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
2 Ring
Rapid
101
85A
4.30
3.00
313 g/h
218 g/h
1.90
0.60
20 28-3035
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0073 g/h 0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
2 Ring
Rapid
101
85A
4.30
3.00
307 g/h
214 g/h
1.90
0.60
25 37 45
Semi-rapid66A 1.75 125 g/h 0.35
Auxiliary501.0071 g/h 0.30
II2H3B/P
RU - SK - CZ -
UA - RO - BG -
HR - SI - RS
NATURAL GAS
(Methane) G20
2 Ring
Rapid
168
125A
4.80
3.00
457 l/h
286 l/h
2.20
0.60
17 20 25
Semi-rapid 97A1.75167 l/h 0.35
Auxiliary78A 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
2 Ring
Rapid
101
85A
4.80
3.00
313 g/h
218 g/h
1.90
0.60
25 30 35
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0073 g/h 0.30
II2HS3B/P
HU*
NATURAL GAS
(Methane) G20
2 Ring
Rapid
158B
119
4.80
3.00
457 l/h
286 l/h
2.35
0.70
20 25 33
Semi-rapid 92A1.75167 l/h 0.40
Auxiliary741.0095 l/h 0.35
NATURAL GAS G25.1
2 Ring
Rapid
175B
135
4.80
3.00
531 l/h
332 l/h
2.20
0.60
18 25 33
Semi-rapid100A1.75194 l/h0.35
Auxiliary811.00111 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
2 Ring
Rapid
101
85A
4.30
3.00
313 g/h
218 g/h
1.90
0.60
20 30 35
Semi-rapid66A 1.75 127 g/h 0.35
Auxiliary501.0073 g/h 0.30
Type of gas usedModel congurationRated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
II2H3+
IT - ES - GR -
PT - AE - MA -
TN - DZ
G20 20 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/
.52
G30 28-30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.94
G31 37 mbar2C - 1 R - 2 SR - 1 AUX 11.80842 g/h 23.80
II2H3B/P
RU - SK - CZ -
UA - RO - BG -
HR - SI- SR
G20 20 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/
.52
G30/G31 30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.94
II2HS3B/P
HU*
G20 25 mbar2C - 1 R - 2 SR - 1 AUX 12.301172 l/
.52
G25.1 25 mbar2C - 1 R - 2 SR - 1 AUX12.30 1362 l/h 8.187
G30/G31 30 mbar2C - 1 R - 2 SR - 1 AUX 11.80858 g/h 30.95
* if the appliance is intended to be in use in Hungary, injectors already assembled (G20 - 20mbar) must be replaced according
to Hungarian market regluation,
available in Instruction for User. Injectors for replacement are available in the kit. Please refer to User Manual information
. Injector replacement must be done
by a qualied technician.
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz - 0,6 W
WOK ADAPTER (not included,this accessory can be purchased separately from the After-sales Service)
Comentarios a estos manuales