NOTE: should particular local conditions of the delivered gas make the ignition of burner dicult, it is advisable to repeat the operation with the knob turned
to small ame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In this case, repeat the operations
described above.
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: in case of installation of a hood above
the cooktop, please refer to the hood instructions
for the correct distance
860
840
Type of gas
used
INJECTORS TABLE
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz - 0,6 W
LPG 5.0 kPa
839 g/h
LIQUEFIED
PETROLEUM GAS
(Butane)
Model configuration
5 BURNERS
Total rated
consumption
Injector marking
(1/100)
Rated
consumption
Rated heat
capacity
Gas
pressure
Type of gas
used
Type of
burner
75S
57M
43H2
86S
50
25
25
80
5.0
Rapid (R)
Semi-rapid (S)
Auxiliary (A)
2 Ring (DCC)
1R -2S -1A-1DCC
mm g/h g/h
218
120
90
291
kPa
WOK ADAPTER and PRODUCT LID
(not included,this accessory can be purchased separately from the After-sales Service).