INJECTORS TABLE
CATEGORY II2H3B/P II2HS3B/P (HU)
Type of gas
used
Type of
burner
Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity kW
Gas pressure
mbar
kW min. rat. max.
NATURAL GAS
(Methane) G20
Rapid125A3.00286 l/h 0.60
17 20 25Semi-rapid 97A1.75167 l/h 0.35
Auxiliary78A 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Rapid85A 3.00 218 g/h 0.60
25 30 35
Semi-rapid 66A1.75127 g/h 0.35
Auxiliary501.00 73 g/h0.30
HU*
NATURAL GAS
(Methane) G20
Rapid119 3.00 286 l/h0.70
20 25 33Semi-rapid 92A1.75167 l/h 0.40
Auxiliary741.00 95 l/h0.35
NATURAL GAS
G25.1
Rapid135 3.00 332 l/h0.60
18 25 33Semi-rapid 100A 1.75 194 l/h0.35
Auxiliary811.00111 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Rapid85A 3.00 218 g/h 0.60
20 30 35
Semi-rapid 66A1.75127 g/h 0.35
Auxiliary501.00 73 g/h0.30
Type of gas used Model
conguration
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G20 20 mbar1 R - 2 SR - 1 AUX7.50715 l/h 9.52
G30/G31 30 mbar1 R - 2 SR - 1 AUX7.50545 g/h 30.94
HU*
G20 25 mbar1 R - 2 SR - 1 AUX7.50715 l/h 9.52
G25.1 25 mbar1 R - 2 SR - 1 AUX7.50831 l/h 8.187
G30/G31 30 mbar1 R - 2 SR - 1 AUX7.50545 g/h 30.95
TRIC SUPPLY: 220-240 V ~ 50/60 Hz - 0,6 W
f the appliance is intended to be in use in Hungary, injectors already assembled (G20 - 20mbar)
must be replaced according to Hunga
rian market regluation, available in Instruction for User.
ctors for replacement are available in the kit. Please refer to User Manual information.
Injector replacement must be done by a qualied technician.
WOK ADAPTER (not included,this accessory can be purchased separately from the After-sales Service)