GB
17
Burner and nozzle specifications
Table 1
Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal
power
kW
(p.c.s.*
Thermal
power
kW
(p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
Ridot. Nomin. (mm) (mm) *** ** Nomin. (mm)
Reduced Fast (RR) 100 0,70 2,60 41 80 189 186 2,60 110 (Y) 248
Semi Fast (S) 75 0,40 1,90 30 70 138 136 1,90 106 181
Auxiliary (A) 55 0,40 1,00 30 50 73 71 1,00 79 95
Triple Crown (TC) 130 1.30 3,30 57 87 236 232 3,60 131 309
Ultrarapid (UR) 100 0,70 3,40 41 91 240 236 3,40 123 314
Semi-Fishburner (SP) — 0,70 1,50 41 60 109 107 1,50 88 143
Double flame (DCDR internal) 30 0,40 0,90 30 44 65 64 0,90 74 86
Double flame (DCDR external)
2 nozzle
130 1,30 4,10 57 70 298 293 4,10 110 390
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
DC
S
A
SP
DC
TC
S
A
DC
S
A
DC TC
PH 760 RF/HA PH 750 RT GH/HA PH 741 RQO GH/HA PH 720 RT/HA
PH 760 RF GH/HA
PZ 760 RF/HA
DC TC
S
RR
UR
S
S
A
RR
TC
S
S
A
RR
S
A
S
SP
PH 730 RT/HA PH 750/HA PH 750 T/HA PH 760 F/HA
PH 750 T GH/HA PH 760 F GH/HA
The hob can only be installed above built-in ovens with a cooling ventilation system.