CLEANING THE HOB PARTS (Appendix A) – See drawing below for parts removal guides.
To reinstall the parts (grids, caps, rings and burners) reverse depicted operation.
INJECTORS TABLE CATEGORY II2L3B/P
Type of
gas used
Type of
burner
Injector
marking
Primary Air
adjusting
(X)
(mm)
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
mbar
min. nom.
max.
NATURAL GAS
(Methane) G25
Ultra-Rapid 148 4.20 465 l/h 0.85
20 25 30
Rapid 127 3.00 332 l/h 0.85
Semi-Rapid BR 102 15 1.90 210 l/h 0.45
Semi-Rapid FL 87 1.40 155 l/h 0.45
Auxiliary 76 1.00 111 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Ultra-Rapid 101 4.20 305 g/h 0.85
25 30 35
Rapid 84 3.00 218 g/h 0.85
Semi-Rapid BR 71 15 1.90 138 g/h 0.50
Semi-Rapid FL 58 1.40 102 g/h 0.50
Auxiliary 50 1.00 73 g/h 0.30
Type of gas used Model
configuration
Rated thermal
flow rate (kW)
Total rated
consumption
Air required (m
3
) for
burning 1 m
3
of gas
G25 25 mbar 5 burners 11.50 1273 l/h 8.187
G30/G31 30 mbar 5 burners 11.50 836 g/h 30.94
ELECTRIC SUPPLY: 220-240 V ~ 50/60 Hz