BURNERS AND NOZZLES SPECIFICATIONS
* At 15°C and 1013 mbar-dry gas
Propane G31 H.s. = 50,37 MJ/kg
Butane G30 H.s. = 49,47 MJ/kg
Methane G20 H.s. = 37,78 MJ/m
3
(situated under the hob or at the end of the instruction booklet).
Make sure that the local supply voltage corresponds to the
voltage indicated on the rating plate.
Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect to a suitable socket. To connect directly
to the mains supply, a double-pole switch with a contact
separation of at least 3 mm suitable for the load and
complying with current standards and regulations, must
be fitted between the appliance and the mains supply outlet.
The yellow-green earth wire must not be interrupted by the
switch. The supply cable must be in such a position that no
part of it can reach a temperature of 50 °C above room
temperature. For installation above a built-under oven, the
hob and the oven must be connected separately to the
electricity supply both for safety reasons and for easy
removal of the oven if necessary. Do not use adapters or
shunts as they could cause heating or burning. Before
connecting to the power supply, make sure that:
the limiter valve and the domestic system can withstand
the load from the appliance (see rating plate);
the supply system is efficiently earthed according to
standards and laws in force;
the socket or double-pole switch are easily accessible when
the appliance is installed.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E” or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked L” or
coloured Red. Connect the Blue wire to the terminal marked
N or coloured Black. FAILURE TO OBSERVE THE
ACCIDENT-PREVENTION REGULATIONS RELIEVES THE
MANUFACTURER OF ALL LIABILITY.
Replacing the cable
Use a rubber cable of the type H05VV-F with a suitable
cross section 3 x 1.5 mm². The yellow-green earth wire
must be 2-3 cm longer than the other wires.
ELECTRICAL CONNECTION
ENERGY LABEL
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
Energy consumption for Natural convection
heating mode: Convection
Declared energy consumption for Forced convection Class
heating mode: Fan assisted
TECHNICAL SPECIFICATIONS
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
C.Rapid
100 3.00 0.7 40 86 218 214 116 286
B. Semi-rapid
75 1.65 0.4 30 64 120 118 96 157
A. Auxiliary
55 1.00 0.3 27 50 73 71 71 95
I. Double flame DC DR (internal)
30 0.90 0.4 30 44 65 64 74 86
I. Double Flame DC DR (external)
130 4.10 1.3 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25