After unpacking the hob, make sure that it has not been damaged during transport. In the event of problems, contact the
dealer or your nearest After-sales Service.
These instructions are only valid for the countries whose symbols is given on the data plate (under the hob).
TECHNICAL INFORMATION FOR THE INSTALLER
This product can be embedded in a worktop 20 to 50 mm thick.
If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the
work surface. This panel, that has to close completely the cutout in order to avoid any contact with the bottom
part of the hob, must be positioned at a maximum distance of 150 mm below the upper surface of the work
surface but, in no case less than 20 mm from the bottom of the hob. In the case that you intend to install an oven
beneath the hob, make sure that it is manufactured by Whirlpool and equipped with a cooling system. The
manufacturer declines all liability if another brand oven is installed beneath the hob.
Before installation, make sure that:
- the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the
rating plate and injector table);
- the outer surfaces of the furniture or appliances adjacent to the hob are heat resistant according to local regulations;
- this appliance is not connected to a fume exhaust device. It shall be installed in accordance with current installation
regulations. Particular attention shall be given to the relevant requirements regarding ventilation.
- combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans.
GAS CONNECTION
INSTALLATION
WARNING
This operation must be performed by a qualified technician or authorised person.
The gas supply system must comply with local regulations to the
current relevant gas standard (AS/NZS 5601 current edition).
The connection of the hob to the gas pipe network or gas cylinder must be
made by means of a rigid copper or steel pipe with fittings complying with
local regulations.
WARNING: THIS PRODUCT IS NOT SUITABLE FOR A FLEXIBLE HOSE
CONNECTION.
After connection to the gas supply, check for leaks with soapy water.
Light up the burners and turn the knobs from max position to minimum
position to check flame stability.
As part of the installation procedure, it is necessary for the installer to check
pressure. If the pressure isn't correct, it will affect the operation and
performance of the appliance.
For LPG / PROPANE models the gas supply for the hotplate must be regulated to
a pressure of 2.75kPa. The gas inlet connection fitting is ½” tapered B.S.P male
thread (in compliance with ISO 7 thread).
For NG models the gas supply is connected to a regulator which is supplied. The
inlet connection has ½” B.S.P male thread. IT IS ESSENTIAL THAT THE ELBOW ON
THE APPLIANCE BE HELD FIRMLY WITH A SPANNER. DO NOT OVER TIGHTEN. The
regulated pressure for NG is 1.00kPa.