Whirlpool AKR 353/IX Instrucciones de uso Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
HOW TO USE THE HOB
WARNING

IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.


After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.This burner safety device shuts off the gas supply to



NOTE:

In this case, repeat the operations
described above.

NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a
minimum of 530 mm.
if the distance “A” between the wall cabinets is greater
than the width of the hob, the height “B” must be a
minimum of 400 mm.
In case of installation of a hood above the hob, please refe
r
to the hood instructions fot the correct distance.
+3H2II YROGETACELBAT SROTCEJNI
Type of gas
used
Type of burner Injector
marking
Rated thermal
ow rate
Rated
consumption
Reduced heat
capacity
Gas pressure
mbar
.xam.tar.nimWkWk
NATURAL GAS
(Methane) G20
Power Burner
138 A
3.50 333 l/h1.55
17 20 25Semi-rapid
95 Z
1.75 167 l/h0.35
Auxiliary
72 X
1.00 95 l/h0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Power Burner P 93 3.50 254 g/h1.55
20 28-3035Semi-rapid631.75127 g/h0.35
Auxiliary 50 1.00 73 g/h0.30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Power Burner P 93 3.50 250 g/h1.55
25 37 45Semi-rapid631.75125 g/h0.35
Auxiliary 50 1.00 71 g/h0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
G20 20 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 762 l/h9.52
G30 28-30 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 581 g/h 30.94
G31 37 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 571 g/h23.80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz 0,6W
Vista de pagina 5
1 2 3 4 5 6 7 8 9 10 11 ... 67 68

Comentarios a estos manuales

Sin comentarios