PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of dierent diameters. For better burner perfor-
mance, please stick to the following rules:
- Use pots and pans with bottoms the same width as that of the
burners or slightly larger (see table on the right).
- Only use at-bottomed pots and pans.
- Use the correct amount of water for cooking foods and keep the
pot covered.
- Make sure pots on the grates do not protrude beyond the edge of
the hob.
IMPORTANT: improper use of the grids can result in damage to the
hob: do not position the grids upside down or slide them across
the hob.
Do not use:
- Cast iron griddles, ollar stones, terracotta pots and pans.
- Heat diusers such as metal mesh, or any other types.
- Two burners simultaneously for one receptacle (e.g. sh kettle).
Burner Pot Ø
Power Burner From 24 to 26 cm
Semi-rapid From 16 to 24 cm
Auxiliary From 8 to 14 cm
HOW TO USE THE HOB
WARNING
Do not let the burner ame extend beyond the edge of the pan.
IMPORTANT: WHEN THE HOB IS IN USE, THE ENTIRE HOB AREA MAY BECOME HOT.
• To ignite one of the burners, turn the relative knob anti-clockwise to the maximum ame setting.
• Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5-10 seconds to allow proper device operation.
This burner safety device shuts o the gas supply to the burner if the ame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
• The knob must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not remain
lit, wait at least one minute before trying to light it again.
In the event of the burners ames being accidentally extinguished, turn o the burner control and do not attempt to
reignite it for at least one minute.
NOTE: should particular local conditions of the delivered gas make the ignition of burner dicult, it is advisable to
repeat the operation with the knob turned to small ame setting.
The burner might go out when the knob is released. This means that the safety device has not warmed up enough. In
this case, repeat the operations described above.
DIMENSIONS AND DISTANCES TO BE MANTAINED MM
NOTE: if the distance “A” between the wall cabinets is
between 600 mm and 730 mm, the height “B” must be a minimum of
530 mm.
if the distance “A” between the wall cabinets is greater than the wi-
dth of the hob, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the
hood instructions fot the correct distance.
INJECTORS TABLE
Type of gas used Type of
burner
Injector
marking
Rated ther-
mal ow rate
Rated
consump-
tion
Reduced heat
capacity
Gas pressure mbar
kW kW min. rat. max.
Power Burner 138 A 3.50 333 l/h 1.55
NATURAL GAS
(Methane) G20
Semi-rapid 95 Z 1.75 167 l/h 0.35 17 20 25
Auxiliary 72 X 1.00 95 l/h 0.30
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
Power Burner 93 P 3.50 254 g/h 1.55
Semi-rapid 63 1.75 127g/h 0.35 25 30 35
Auxiliary 50 1.00 73 g/h 0.30
Type of gas used Model conguration
4 BURNERS
Rated thermal
ow rate (kW)
Total rated
consumption
Air required (m3) for
burning 1 m3 of gas
G20 20 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 762 l/h 9.52
G30/G31 30 mbar 1 PB 2C - 2 SR - 1 AUX 8.00 581 g/h 30.94
ELECTRIC SUPPLY: 220-240V ~50/60Hz 0,6W