AKT 352 PRODUCT DESCRIPTION SHEET
GB
5019 319 01511
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
PL
LIGHTING THE BURNERS
• To ignite one of the burners, turn the relative knob anticlockwise to the maximum flame setting .
• Press the knob against the control panel to ignite the burner.
• After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling over,
etc.).
• The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For optimum burner performance, observe the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
1
2
5
3
4
1. Removable grid(s)
2. Semi-rapid burner
3. Rapid burner
4. Semi-rapid burner control knob
5. Rapid burner control knob
SYMBOLS
Tap closed
Max. flame
Min. flame
Burner Pot Ø
rapid from 24 to 26 cm
semi-rapid from 16 to 22 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In the event a hood is fitted above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2ELwLs3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Ty p e o f g a s u s e d Ty p e o f
burner
Injector
marking
Nominal heating
capacity
kW
Nominal
consumption
Reduced
heating capacity
kW
Gas pressure
(mbar)
min. nom. max.
NATURAL GAS
(Methane) G20
rapid
semi-rapid
128
95
3.00
1.65
286 l/h
157 l/h
0.70
0.40
16 20 25
NATURAL GAS
G2.350
rapid
semi-rapid
170
129
3.00
1.65
397 l/h
218 l/h
0.60
0.35
10 13 16
NATURAL GAS
G27
rapid
semi-rapid
143
106
3.00
1.65
344 l/h
189 l/h
0.60
0.35
16 20 23
LIQUEFIED
PETROLEUM GAS
(Butane) G30
(Propane) G31
rapid
semi-rapid
88
63
3.00
1.65
218 g/h
120 g/h
0.70
0.40
25 37 45
Type of gas used Model configuration
2 BURNERS
Nominal heating
capacity
kW
Total nominal
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 1 R - 1 SR 4.65 443 l/h 9.52
G2.350 13 mbar 1 R - 1 SR 4.65 615 l/h 6.85
G27 20 mbar 1 R - 1 SR 4.65 533 l/h 7.80
G30/G31 37 mbar 1 R - 1 SR 4.65 338 g/h 30.94