INSTALLATION
REPAIRS
Replacing the supply cable
Turn the hob over and unhook the terminal board
coverbyputtingascrewdriverinthetwohooks“A.
Open the cable gland by unscrewing screw “F”,
unscrew the terminal screws and remove the cable .
The new supply cable, of suitable type and section, is
connected to the terminal board following the
diagrams shown below.
SECTION OF THE SUPPLY CABLES AND
CONNECTION DIAGRAM
Use H05RR-F cables. The diameter of the supply
cable must not be greater than 9 mm.
For models ETN 4240 ETK 4240
230 V
Ù
50/60 Hz 3 x 1,5 mm
2
230 V
For models ETN 4240 CH ETK 4240 CH
400 V
Ù
50/60 Hz 3 x 1,5 mm
2
400 V
A
28