If a hood is installed above the hob, read the instructions for fitting the hood where it indicates the correct
distances to be complied with.
Installation distances and measurements (mm)
min. R 6,5
63 min.
7
Category
II2L3B/P
Type of gas used Type of Injector Nominal heat Nominal Reduced heat Gas presssure
burner marking flow kW consumption flow kW (mbar)
min. nom. max
NATURAL GAS wok 3C 151 4,00 443 l/h 1,55
(Methane) rapid 132 3,00 332 l/h 0,60
G25 semi-rapid 100 1,65 183 l/h 0,35
20 25 30
auxiliary 79 1,00 111 l/h 0,35
LIQUID wok 3C 102 4,00 291 g/h 1,55
PETROLEUM GAS rapid 87 3,00 218 g/h 0,60
(Butane) G30 semi-rapid 67 1,65 120 g/h 0,35
25 30 35
(Propane) G31 auxiliary 50 1,00 73 g/h 0,35
Type of gas used Configuration Nominal heat Overall nominal Required air (m
3
)
model flow kW consumption for the combustion 1 m
3
of gas
G25 25 mbar 3C - R - SR - SR - AUX 11,30 1252 l/h 8,187
G30/G31 30 mbar 3C - R - SR - SR - AUX 11,30 822 g/h 30,94
Electric Power: 230 V ~ 50 Hz