Whirlpool KHMP5 77510 Instrucciones de uso Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
I
f a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Note: If the distance A” between the wall cupboards in the kitchen is between 600mm and 730mm, the
height “B” must be at least 530mm. If the distance Abetween the wall cupboards is greater than the
width of the hob, the height “B” must be at least 400 mm.
Hood and cabinetry clearances (mm)
6
Category
I2E
Electric supply:220-240 V ~ 50/60 Hz 0,6W
Injectors table
Type of gas used
Type of
burner
Injector
marketing
Nominal heat
flow kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
2 ring
(outer + inner)
Inner
165H1+70H1
70H1
5,80
0,90
552 l/h
86 l/h
2,20
0,30
17 20 25
rapid 125A 3,00 286 l/h 0,60
semi-rapid 97A 1,75 167 l/h 0,35
auxiliary 78C 1,00 95 l/h 0,30
Type of gas used
Model configuration
5 burners 2C 5,8kW
Rated thermal flow rate kW Total rated consumption
Air required (m
3
) for burning
1 m
3
of gas
G20 20 mbar 2C-1R-2SR -1AUX 13,3 1267 l/h 9,52
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 13 14

Comentarios a estos manuales

Sin comentarios