Burner and nozzle specifications
DATA PLATE
Dimensions
Breite 43,5 cm
Höhe 32 cm
Tiefe 41,5 cm
Volumen
Liter 53
Electrical
connections
voltage: 230V ~ 50Hz maximum
power absorbed 2850W
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens Norm EN 50304
Energy consumption for Natural
convection:
heating mode: Convectional
Declared energy consumption for
Forced convection Class:
heating mode: F
ast cooking
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-pa-
ss
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Nozzler
1/100
Flow*
l/h
Nom. Red. (mm)G30/31 (mm)
Fast
(Large) (R)
100 3.00 0.7 40 86 218 116 286
Sem i Fast
(Medium) (S)
75 1.65 0.4 30 64 120 96 157
Auxiliary
(Small) (A)
55 1.00 0.430 50 73 71 95
Triple Crown (TC) 130 3.
25 1.3 57 91 236 124 309
Supply pressures Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
20
17
25
* At 15°C and 1013 mbar-dry gas
Propane G31 H.s. = 50,37 MJ/kg
Butane G30 H.s. = 49,47 MJ/kg
Methane G20 H.s. = 37,78 MJ/m
3