Burner and nozzle specifications
Table 1 Liquid gas Natural gas
Burner Burner
diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow *
g/h
Nozzle
1/100
(mm)
Flow *
l/h
Nomin. Reduc. *** **
Fast R
(large)
100 3.00 0.7 40 86 218 214 116 286
Semi-Fast S
(medium)
75 1.65 0.4 30 64 120 118 96 157
Auxiliary A
(small)
55 1.00 0.3 30 50 73 71 71 95
Supply
pressures
Minimum (mbar)
Nominal (mbar)
Maximum (mbar)
30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m
3
A
R
S
S
Ø180
A
R
S
S
R
PI 941 A PI 950 A
PI 941 AS PI 950 AS
DATA PLATE
Electrical
connections
see data plate
This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90
(Gas) and subsequent
amendments.
- 2002/96/EC