GB
! If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adapting the grill
Replacing the grill burner
nozzle:
1. Remove the oven burner
after loosening screw V (see
gure).
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner (see  gure) or
preferably with a 7 mm socket
spanner, and replace it with a new nozzle that is
suited to the new type of gas (see Burner and nozzle
speci cations table).
! Be careful of the spark plug wires and the
thermocouple tubes.
! The oven and grill burners do not require primary air
adjustment.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
V
I
S
S
R
A
KN3G2/EX
KN3G210/EX
KN1G21/EX
KN3M21/EX
S
R
A
Ø180
WARNING! The glass lid can break
in if it is heated up. Turn off all the
burners and the electric plates before
closing the lid. *Applies to the models
with glass cover only.
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x38x44 cm
Volume
57 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
90/396/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Table 1 Gaz liquide Gaz naturel
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm)
Fast
(Large)(R)
100 3,00 0,7 41 87 218 214 128 286
Semi Fast
(Medium)(S)
75 1,90 0,4 30 70 138 136 104 181
Auxiliary
(Small)(A)
51 1,00 0,4 30 52 73 71 76 95
Oven - 2.80 1.0 46 80 204 200 119 267
Grill - 2,30 - - 75 167 164 114 219
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
“regulators for channelled gas”.