Replace all the components by repeating the steps in
reverse order.
c) Minimum regulation of the hob burners:
Turn the tap to minimum;
Remove the knob and adjust the regulation screw,
which is positioned in or next to the tap pin, until the
flame is small but steady.
Burner and Nozzle Specifications
Table 1 Natural Gas GZ 50 Natural Gas GZ 35 GPB-B
Burner Diameter
(mm)
Thermal power
(p.c.i.*)
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
g/h
kW (mm) (mm) (mm)
Triple Crown (TC) 130 2,8 133 297 197 413 91 233
Fast (Large)(R) 100 2,7 116 285 158 398 86 225
Semi Fast
(Medium) (S)
75 1,7 106 180 143 251 70 142
Auxiliary (Small)
(A)
55 0,9 79 95 106 133 50 75
Supply
Pressures
Minimum (mbar)
Nominal (mbar)
Maximum (mbar)
16
20
25
10
13
16
29
36
44
* A 0°C e 1013 mbar-dry gas
GZ 50 p.c.i. 35.9 MJ/
GZ 35 p.c.i. 25.8 MJ/
GPB-B p.c.i. 123.6 MJ/m³
TC
A
S
R
S
S
R
A
C 649 PT.3 U C 649 PV.3 U
C 649 PT.3 XA U
N.B.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
Check that the flame does not go out when you turn
the tap quickly from high to low.
d) Regulating the primary air of the burners: the primary
air of the burners does not need to be regulated.
Important
On completion of this operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compli-
ance with current standards regarding “regulators for chan-
nelled gas.