GB
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x39x 38 cm
Volume
50 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Power supply voltage
and frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
90/396/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/ Off mode)
7
Table of burner and nozzle specifications
S
S
R
A
KNJ1G21S/RO
Table 1-special for Hungary G20 G30
Diameter By-pass
1/100
Thermal
Power kW
Nozzle
1/100
Thermal
Power kW
Flow*
l/h
Nozzle
1/100
Thermal
Power kW
Flow*
l/h
Burner
(mm) (mm) Reduced (mm) (mm)
Fast
(Large)(R)
100 41 0.80 116 3.40 324 86 3.00 218
Semi Fast
(Medium)(S)
75 30 0.50 103 2.20 209 70 1.90 138
Auxiliary
(Small)(A)
55 30 0.50 79 1.15 109 50 1.00 73
Oven -
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
25
20
30
30
20
35
At 15 °C and, 1013 mbar , dry gas
P.C.S. G20 37,78 MJ/m3
P.C.S. G30 49,47 MJ/K
48-49
1.0
107
2.20
209 68 2.00 145
! If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
ENERGY LABEL
and ECODESIGN
Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Standard EN 15181.
Standard EN 30-2-1
Comentarios a estos manuales