N C
M Y
INSTALLATION
Adaptation to different types of gas
If a gas different from that indicated on the label
is used, adapt the cooktop to this new function.
To replace the injectors consult the After-Sales
Service or a trained technician.
Injectors not supplied can be obtained from the
After-Sales Service.
1. Connect the cooktop to the on-off tap with a
tube which is suitable for the gas to be used
according to the regulations in force.
2. Replace the injectors (see Product Card),
proceeding as follows:
x Remove the grids (A).
x Extract the burner bodies (B).
x With a Ø 7 socket spanner (C) unscrew the
injector to be replaced.
x Replace with the injector provided for t he
new t ype of gas and reassemble in (D).
x Reassemble the burner bodies and the girds.
x Cancel the calibration indication (set for ....
gas) on the rating plate and position the
plate for the new type of gas near the gas
mains connection. This is to be found in the
bag of injectors supplied.
3. Select the type of gas (see Product Card) on
the basis of the injectors selected in point 3,
proceeding as follows:
x Make sure that the button
U
(see Product
Card) is OFF.
x Turn all the knobs to the minimum search
position.
x Keep button -
)
pressed and press button
+
=
3timeswithin 5 seconds then
release. The display shows the type of gas
adjusted in the factory or the last gas
selected.
If the buttons are not selected within 10
seconds, the procedure finishes without
changes.
x To select a different type of gas press
button +
=
choosing according to the
sequence C1 f C2 f C3 f C4 f C5.
f
x To save the type chosen, keep button -
)
pressed down and press button +
=
3 times within 5 seconds then release: the
saving is confirmed by an acoustic signal.
4. Automatically adjust the minima (see Product
Card).
NATIONAL SAFETY REGULATIONS
U.K.
Provision for ventilation
The room containing this appliance should have
an air supply in accordance with the current
B.S. 5440: Part 2 .
All r ooms require a permanent vent in addition
to the openable window. If there are other fuel
burning appliances in the same room, B.S. 5440:
Part 2 should be consulted to determine t he
requisite air vent requirements.
If the appliance is installed in a cellar or
basement, it is advisable to provide an air vent
of effective area 65 cm, irrespective of the
room volume.
Gas Safety Regulations
It is law that all gas appliances are installed by
competent persons in accordance with the
current gas safety regulations. Failure to install
appliances correctly could lead to prosecution.
It is in your own interest, and that of safety, to
ensure that the law is complied with.
The hob should be installed in accordance with
the Gas Safety (Installation and Use)
Regulations, the Building Regulations issued by
the Department of the Environment and the
Building Standards (Scotland) (Consolidation)
Regulations issued by the Scottish Development
Department. In the U.K. CORGI registered
installers work to safe standards of practice.
16