(1) Data obtained at room temperature (20°C), water introduced at 15°C; water quality = 500ppm
(2) Maximum consumption obtained at room temperature=43°C, according to UNE climate classification Class T
(TROPICALISED)
NOTE: Expansion controlled by capillary except in modulars models where it is controlled by means of an
expansion valve.
REFRIGER. LOW FUSE POWER
CHARGE PRESSURE SECURITY COMPRESSOR
MODEL
HIGH PRESSURE
TOTAL
INTENST.
AMPS
(TO INSTALL)
POWER
ABS
MIN. MAX. AVERAGE -2 -1 -2
(GR) (A) (A) (W) (W)
NDP 20 A
345 2 1/5 355
NDP 20 W
285 2 1/5 355
NG 30 A
320 2 1/4 423
NG 30 W
300 2 1/4 423
NG 35 A
360 2 1/4 540
NG 35 W
310 2 1/4 540
NG 45 A
420 3 3/8 550
NG 45 W
365
3
3/8 550
NG DP 60 A
420
15´5 bar 18 bar 2´5 bar
3.5
10
3/8 650
NG DP 60
W
350 3.5 3/8 650
NG DP 80 A
470 3 1/2 780
NG DP 80 W
355 3 1/2 780
NG 110 A
1000 4 7/8 1150
NG 110 W
1000 4 7/8 1150
NG 150 A
1000 4 13/8 1350
NG 150 W
1000 4 13/8 1350
MDP 150 A
1200
5.5
13/8 1500
MDP 150 W
1200
13/8 1500