20
- The Line to base of plug must have a minimum section of 2.5 mm
2
.
- Be sure voltage indicated on rating plate corresponds to that of mains supply.
IMPORTANT!
Supply socket must be properly earthed. Be sure to check standard for country were
appliance is going to be installed.
OPERATION
Preliminary Check
a) Is machine levelled?
b) Are voltage and frequency of mains supply the same as indicated on rating plate?
c) Is drainage system functioning?
d) Is air circulation and room temperature adequate? (**Air cooled models)
TEMPERATURE ROOM WATER
MAXIMUM 43 C 35ºC
MINIMUM 5º C 5ºC
a) ** Is water pressure adequate?
MINIMUM 0.7 Bar
MAXIMUM 6 Bar
NOTE: To install a pressure reducer If water inlet pressure is more than 6 bar.
ATTENTION: Check that voltage and mains frequency are the same as in the rating plate.