Form 1: The tightening torque needed for tightening nut
Examine the connection pipe to see if it had gas leakage, then take the treatment of heat insulation, as
shown in the fig.3.
Only use median sponge to entwine the wiring interface of the gas pipe and heat preservation sheath of
the gas collection tube.
G. Drainage hose
1. Install the drain hose
The diameter of the drain hose should be equal or bigger than the connection pipe's. (The diameter of
polythene pipe: Outer diameter 25mm Surface thickness 1.5mm)
Drain hose should be short and drooping gradient should at less 1/100 to prevent the formation of air
bubble.
If drain hose cannot has enough drooping gradient, drain raising pipe should be added.
To prevent bent of the drain hose, the distance between hoisting stand should is 1 to 1.5m.
Use the drain hose and clamp attached. Insert the drain hose to the
drain vent, and then tighten the clamp.
Entwine the big sponge on the clamp of drain hose to insulate heat.
Heat insulation should be done to indoor drain hose.
Diameter (inch) Surface thickness (mm) Tightening torque (N.m)
Ø 1/4" 0.5 15-30 (N.m)
Ø 3/8" 0.71 30-40 (N.m)
Ø 1/2" 1 45-50 (N.m)
Ø 5/8" 1 60-65 (N.m)
Ø 3/4" 1 70-75 (N.m)
(correct) 1/25 to 1/100 down-slope
(wrong)
Clamp (accessory)
Sponge (5Tx270x270) (accessory)