EN7
IMPORTANT: For installation in worktops made of marble or similar materials, do not use the screws provided, but contact the after-sales service and request
bonding kit 4812 310 19277.
After bonding the brackets in the position indicated, leave the silicone to dry for around 24 hours before proceeding with installation of the appliance.
ELECTRICAL CONNECTION
WARNING
Disconnect the appliance from the power supply.
Installation must be carried out by qualied personnel who know the current safety and installation
regulations.
The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the regulations
provided in this chapter.
The power cable must be long enough to allow the hob to be removed from the worktop.
Make sure the voltage specied on the dataplate located on the bottom of the appliance is the same as that of the home.
Do not use extension cords.
Connection to the terminal block
If the hob is already provided with the two power supply cables required, follow the instructions included in the supply cable bag.
Connect the cables to the two terminal blocks on the underside of the appliance.
IMPORTANT:
only for 400 V 3N connection~ use one power supply cable only (connecting it to the terminal block of the main electronic module) in addition to 3 x 1.5mm
2
wiring for connecting the main terminal block to that of the auxiliary electronic module. For electrical connection, follow the instructions enclosed with the 3 x 1.5mm
2
wiring.
3 x 1.5 mm
2
400 V 3N ~ 230 V ~ / 230-240 V ~ / 400 V 2N ~ / 230 V 3 ~
For electrical connection, use an H05RR-F cable as specied in the table below.
Wires Number x size
220-240V ~ +
380-415V 2N~ +
220-240V 3~ +
380-415V 3N~ +
3 x 4 mm
4 x 1,5 mm
5 x 1,5 mm
4 x 1,5 mm
CBA
Connect the yellow/green earth wire to the terminal with the symbol .
This wire must be longer than the other wires.
1. Remove the terminal block cover (A), undoing the screw and inserting the cover in the terminal block hinge (B).
2. Strip approx. 70 mm of sheath from the power supply cable.
3. Strip approx. 10mm of sheath from the conductors. Insert the power cable in the cable clamp and connect the wires to the terminal block as indicated in
the connection diagram located near it.