Burner and nozzle characteristics
Table 1 Natural Gas GZ 50 Natural Gas GZ 35 GPB-B
Burner Diameter
(mm)
Thermal power
(p.c.i.*)
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
g/h
kW (mm) (mm) (mm)
Triple Crown (TC) 130 2,8 133 297 197 413 91 233
Fast (Large)(R) 100 2,7 116 285 158 398 86 225
Semi Fast
(Medium) (S)
75 1,7 106 180 143 251 70 142
Auxiliary (Small)
(A)
55 0,9 79 95 106 133 50 75
Supply
Pressures
Minimum (mbar)
Nominal (mbar)
Maximum (mbar)
16
20
25
10
13
16
29
36
44
* A 0°C e 1013 mbar-dry gas
GZ 50 p.c.i. 35.9 MJ/m³
GZ 35 p.c.i. 25.8 MJ/m³
GPB-B p.c.i. 123.6 MJ/m³