* Application of the simultaneity coefficient in accordance
with EN 335-2-6 norm
Notice: The hob is designed to accommodate jumpers for
the single phase connection (neutral line).
Notice: Should the hob be installed above a built-in oven, the
electrical connection of the oven and hob should be separate,
both for reasons of electrical safety as well as to facilitate
access in the event of oven removal.
Important : After connecting the appliance to the flexible
cable, tighten all the screws on the terminal board.
Make sure the jumpers are installed according to the type of
mains system.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated
on the data plate. When connecting the cable directly to the
mains, install an omnipolar circuit-breaker with a minimum
contact opening of 3 mm between the appliance and the mains.
The omnipolar circuit breaker should be sized according to
the load and should comply with current regulations (the yellow-
green earth wire should not be interrupted by the circuit
breaker). The supply cable should be positioned so that it
does not reach a temperature of more than 50°C with respect
to the room temperature, anywhere along its length. Before
making the connection, check that:
the limiter valve and the home system can support the
appliance load (see data plate);
the mains are properly earthed in compliance with current
directives and regulations;
there is easy access to the socket and omnipolar circuit
breaker, once the hob has been installed.
Electrical connection
· The electrical safety of this appliance can only be
guaranteed if the latter is correctly and efficiently
earthed, in compliance with regulations on electrical
safety. The manufacturer denies all responsibility for
damage resulting from a system which has not been
earthed correctly.
Before powering the appliance, check whether the
technical characteristics featured on the appliance data
plate correspond with those of the electrical system (wire
section, protection devices), which should be suitable for
the appliance maximal power.
Important notice
Disconnect the appliance from the electricity supply
before all operations.
The cable should be sized according to the type of electrical
connection used (see connection diagram below).
Jumpers
Terminal board
Connections
Vol tage
Frequency
Fuses
Diameter
FR-AT-BE-DE-GP-ES-IE-IL-IS-IT-L-
U-RE-FI-GB-GR-PT-SE-MA-NZ-NL
230V-1+N~50 Hz
20 A
2,5 mm²
FR-BE-NO
230V-2~50 Hz
20 A
2,5 mm²
FR-AT-BE-DE-ES-IL-IS-IT-LU-PT-S-
E-MA-NZ-CH-NL-DK
400V-2-N~50 Hz
16 A
1,5 mm²
FR-BE-NO
230V-3~50 Hz
16 A
1,5 mm²
FR-AT-BE-DE-ES-IL-IS-IT-LU-PT-S-
E-MA-NZ-CH-DK-NL
400V-3+N~50 Hz
16 A
1,5 mm²
NL
230V-2+2-N~50 Hz
16 A
1,5 mm²
CY-AU-NZ-KW
240V-1+N~50 Hz
20 A
2,5 mm²
LN
12345
L1 L2
12345
L1 L2 N
12345
L1 L2 L3
12345
L1 L2 L3 N
12345
L1 L2 N2N1
12 34 5
LN
12345
Installation