GB
Table of burner and nozzle specifications
Table 1
Liquid gas
Natural gas
Heating power
kW (H.s.*)
Flow rate * g/h
Burner
Diameter
(mm)
Nomin.
Red.
By-pass
1/100
mm)
Nozzle
1/100
mm)
G30
G31
Nozzle
1/100
(mm)
Flow rate *
l/h
G20
C. Rapid
100 3.00 0.7 40 86 218 214 116 286
B. Semi-rapid
75 1.65 0.4 30 64 120 118 96 157
A. Auxiliary
55 1.00 0.4 30 50 73 71 71 95
D. Triple ring
130 3.25 1.3 57 91 236 232 124 309
Gas oven
4.00 0.8 45 95 291 286 142 381
Supply pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m
3
TECHNICAL DATA
Oven dimensions
(HxWxD)
33x54x38 cm
Volume
68 l
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with
any type of gas shown on
the data plate
EC Directives: 2006/95/EEC
dated 12.12.06 (Low
Voltage) and subsequent
amendments –
2004/108/EEC dated
15/12/04 (Electromagnetic
Compatibility) and
subsequent amendments -
90/369/EEC dated 29/06/90
(Gas) and subsequent
amendments - 93/68/EEC
dated 22/07/93 and
subsequent amendments -
2002/96/EC and subsequent
amendments.