11
MODEL REFRIGERANT
CHARGE
HIGH PRESURE LOW
PRESURE
TOTAL
AMPS
FUSE
RATING
COMPRESSOR
POWER
TOTAL
POWER
MINIMUM MAXIMUM AVERAGE (2) (1) (2)
(gr)
Kg/cm
2
Psi
Kg/cm
2
Psi
Kg/cm
2
Psi (A) (A) (W) (W)
IQ 150 A 500 16 228 17 242 2.5 35 4.2 16 365 660
IQ 150 W 360 16 228 17 242 2.5 35 4.2 16 365 660
IQ 200 A 430 16 228 17 242 2.5 35 4.6 16 440 800
IQ 200 W 400 16 228 17 242 2.5 35 4.6 16 440 800
IQ 400 A 630 16 228 17 421 2.5 35 5.8 16 690 1100
IQ 400 W 440 16 228 17 242 2.5 35 5.8 16 690 1100
IQ 550 A 1050 16 228 17 242 2.5 35 9.2 20 1000 1700
IQ 550 W 1050 16 228 17 242 2.5 35 9.2 20 1000 1700
(1) Data obtained at room temperature (20°C), water introduced at 15°C; water quality = 500ppm
(2) Maximum consumption obtained at room temperature = 43°, according to UNE climate classification
Class T (TROPICALISED).
NOTE: Expansion controlled by capillary, except for model IQ400 and 550 which is controlled by a
thermostatic valve.
Models: ICE QUEEN 400 & 550 380V+III+N
MODEL REFRIGERAN
T
CHARGE
HIGH PRESURE LOW
PRESURE
TOTAL
AMPS
FUSE
RATING
COMPRESSO
R POWER
TOTAL
POWER
404ª MÍNIMA MÁXIMA MEDIA (2) (1) (2)
(GR)
Kg/cm
2
Psi
Kg/cm
2
Psi
Kg/cm
2
Psi (A) (A) (W) (W)
IQ 400 A 635 16
228
17
242
2.3
33.4
3.5 10 750 1350
IQ 400 W 635 16
228
17
242
2.3
33.
4
3.5 10 750 1350
IQ 550 A 1500 16
228
17
242
2.3
33.4
5 16 2200 2x2700
IQ 550 W 1500 16
228
17
242
2.3
33.
4
5 16 2200 2x2700
NOTE: Expansion controlled by a thermostatic valve.