TROUBLESHOOTING
PROBLEM PROBABLE CAUSE SOLUTION
1) Machine not running. A) There is no power. A) Check power source.
B) Water trough is empty. B) Check the water supply.
Check filters.
Open faucet
C) Full bin sensor malfunction. C) Fix/replace sensor.
D) No apparent cause. D) Check: contactor, circuit,
breaker, pressostat, timer,
electric installation and magnetic
micro
E) Timer is faulty. E) Replace.
2) Machine works, but doesn’t make
ice.
A) Refrigerant leak. A) Repair leak and recharge
refrigerant .
B) Faulty compressor. B) Replace compressor.
C) valvula de expansion cerrada o
estropeada or capillary obstructed
C) Open or Replace valve (or
capillary) and dehydrating filter.
D) Water/humidity in refrigerating
system.
D) Charge compressor oil,
replace capillary and dehydrator
(use an anti-acid one), create a
vacuum in the installation, slightly
warm up all components and
charge refrigerant.
3) Machine works inconsistently
A) Water pressure lower than 0’7 BAR
(pressure may sometimes drop greatly
when several taps are opened
elsewhere in premises)
A) For smaller units try regulating
the water trough float. Larger
machines might require
installation of a mains pressure
raising unit.
B) Water pressure is appropriate (0’7 a
6’5 BAR)
B) Regulate water level in trough.
4) Compressor works in intermittent
manner.
A) Condenser is dirty A) Clean condenser.
B) Air circulation obstructed. B) Re-establish air circulation.
C) Defective condenser fan. C) Check and replace fan.
D) Fan pressostat is defective or needs
adjustment.
D) Check and replace/adjust
E) Safety pressostat is defective. E) Check and replace.
F) Compressor start system is
defective.
F) Check and replace.
G) Pressostat valve is defective or
needs adjustment.
G) Adjust, repair or replace
valve.
H) Voltage too low/insufficient line
section
H) Inspect and replace if
necessary.
5) Ice is too wet. A) Room temperature too high (over
35ºC)
A) Relocate unit to a cooler
place.
B) Water temperature too high (over
30ºC).
B) Ensure that filter and inlet tube
are away from heat sources,
such as hot air blown by
machine’s own fan.
C) Poor water quality (over 1500 ppm) C) Lower the water trough. Install
water purifier.
D) Condenser is dirty. D) Clean condenser.
E) Pressure-controlled valve on cooling
water needs adjustment or is defective.
E) Adjust or replace valve.
F) Low compressor output F) Replace compressor.