OPERATION
Preliminary Checks
a) Is machine levelled?
b) Are voltage and frequency of mains supply the same as indicated on rating plate?
c) Is drainage system working properly?
d) Is air circulation and room temperature adequate? (Air-cooled models)
AMBIENT TEMPERATURE WATER TEMPERATURE
MAXIMUM 43° C 35° C
MINIMUM 5° C 5° C
e) Is water pressure adequate?
MAXIMUM 0.7 Kg/cm2
MINIMUM 6 Kg/cm2
ATENTION: Check that voltage and mains frequency is the same as in the rating plate.
Starting up
Once preliminary check has been completed (ventilation, connections, temperature, etc.),
proceed as follows:
1. Remove top cover of unit
2. Open faucet, make sure there are no leaks and check that water level is adequate.
4. Set switch to OFF position.
5. Connect unit.
6. Check for air bubbles in water supply tubing (water trough to evaporator)
IMPORTANT!
Be sure voltage and frequency of mains supply is as indicated on rating plate.
1. Set appliance switch to ON position. All elements should be working except for fan (air-cooled
machines) which will commence operation only when high pressure activates it. All pilot lights
should be switched off except for power display (green), indicating that power is on. Otherwise
check the troubleshooting section of this manual.