d) PURIFIED WATER: A 10% reduction in overall production may occur.
Connecting Unit To Water Source
Use 1.3 m. flexible tube (with the two filters attached) provided. NOTE: We advise using a
single faucet fixture.
Water pressure should be between 0.7 and 6 Kgs/cm2. (10/85 Psi.)
If water pressure exceeds these values, installation of appropriate corrective units will be
necessary.
It is important that water tubing does not come close to or in contact with any heat sources or
heat generated by unit as this could decrease production.
Connecting Unit To Drain (Water -cooled Models)
Drain must be located at least 150mm below machine level. Drain tube must have an inner
diameter of 30mm and a minimum gradient of 3 cm per metre.(3%)
Electrical connection
Unit is provided with a 1.5 m cord and Schucko socket (except for models IQ550 and IQ1100).
A switch and adequate fuses should be installed. Nominal voltage and intensity are indicated on
rating plate as well as on this manual's technical pages. Voltage fluctuations greater than 10%
can cause problems or prevent machine from starting.
Line to base of plug must have a minimum section=2.5 mm2 for models up to IQ 200 and 4
mm2 for other models.
Be sure voltage indicated on rating plate corresponds to that of mains supply.
IMPORTANT!
Supply socket must be properly earthed. Be sure to check standard for country where appliance
is going to be installed.
Assembling the dispersion cone
This device spreads ice evenly so it does not pile up
beneath exit tube. Its position can be altered to
redirect ice, and hence prevent the pyramid effect”.