16
GB
The screws for the alignment springs must remain
accessible.
In order to adhere to safety standards, the appliance
must not come into contact with electrical parts once it
has been installed.
All parts that ensure the safe operation of the appliance
must not be removable without
the aid of a tool.
Electrical connection
The electrical connection of the hob and any built-in
oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
Terminal board
On the lower part of the
appliance there is a connection
box for the different types of
electricity supply (the picture is
only an indication and is not an
exact representation of the
purchased model).
Single-phase connection
The hob is equipped with a pre-connected electricity
supply cable, which is designed for single-phase
connection. Connect the wires in accordance with
the instructions given in the following table and
diagrams:
Other types of connection
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
380V +N ~ 50 Hz
230V 3 ~ 50 Hz
380V + 2N ~ 50 Hz
Connect the wires in accordance with the instructions
given in the following table and diagrams:
If the mains supply corresponds with one of the following:
Voltage and mains frequency
400V 3 - N ~ 50 Hz
proceed as follows:
The cable provided is not suitable for the following
types of installation.
1. Use a suitable supply cable, H05RR-F or higher, with
the
right dimensions (cable section: 25 mm).
2. To open the terminal board, insert a screwdriver into
the side tabs of the cover (see Terminal board picture).
3. Loosen the cable clamp screw and the terminal board
screws according to the type of connection required and
position the connection supports as shown
in the
following table and diagrams.
4. Position the wires according to the following table and
diagrams and connect the appliance by tightening all
the screws for the springs as much as possible.
5. Secure the power supply cable by fastening the cable
clamp screw, then put
the cover back on.
Three-phase 400
UNDERSIDE OF HOB
Voltage and
mains frequency
Electrical cable Wire connection
230V 1+N ~
50 Hz
: yellow/green;
N: the two blue wires
together
L: brown and black
together
Voltage and
mains frequency
Electrical cable Wire connection
400V - 2+N ~
50 Hz
230V 3 ~
50Hz
: yellow/green;
N: the two blue wires together
L1: black
L2: brown
400V - 2+2N ~
50 Hz
: yellow/green;
N1: blue
N2: blue
L1: black
L2: brown
Voltage and
mains frequency
Electrical connections Terminal board
400V 3-N ~
50 Hz
Three-phase 400
5
1
2
3
4
U-bolt
connection support
Phase PhasePhase Neutral Earth
Comentarios a estos manuales