PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
230-240V~ 50Hz
(Total electrical heat input: 6,0 - 6,8 kW)
Burners
may be adapted for use with any type
of gas shown on the data plate.
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
implementing Directive 2009/125/EC.
Standard EN 60350-1,
Standard EN 30-2-1,
Standard EN 50564
Declared energy consumption for
Forced convection Class –
heating mode: Fan assisted.
Volume
lt. 61
Energy
Label e
Ecodesign
TECHNICAL DATA (1
st
Oven)
Oven dimensions
HxLxP
36,6 x 40,6 x 40,9 cm
Voltage and
frequency
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC dated 12/12/06 (Low
Voltage) and subsequent amendments.
- 2004/108/EC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments.
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EU and subsequent
amendments.
- 1275/2008 standby/off mode.
230-240V~ 50Hz
(Total electrical heat input: 6,0 - 6,8 kW)
Burners
may be adapted for use with any type
of gas shown on the data plate.
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
implementing Directive 2009/125/EC.
Standard EN 60350-1,
Standard EN 30-2-1,
Standard EN 50564
Energy consumption for Natural
convection – heating mode:
Convection mode
Volume
lt. 63
Energy
Label e
Ecodesign
TECHNICAL DATA (2
nd
Oven)
Oven dimensions
HxLxP
34,0 x 40,8 x 44,8 cm
Voltage and
frequency
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC dated 12/12/06 (Low
Voltage) and subsequent amendments.
- 2004/108/EC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments.
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EU and subsequent
amendments.
- 1275/2008 standby/off mode.
Liquid GasNatural Gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin. Ridot. (mm) (mm) ***** (mm)
HOTPLATE - Semi Rapid - Front Left
HOTPLATE - Rapid - Rear Left
HOTPLATE - Work Outer - Centre Front
HOTPLATE - Work Inner - Centre Front
HOTPLATE - Auxiliary - Centre Rear
HOTPLATE - Double Face - Front Right
HOTPLATE - Double Face - Rear Right
75
100
130
35
50
-
-
1,90
3,00
4,10
1,00
1,00
1,50
1,50
0,40
0,70
1,50
0,40
0,40
0,40
0,40
35
44
63
24
24
35
35
65
86
70 x 2
44
50
60
60
138
218
298
73
73
109
109
136
214
293
71
71
107
107
102 Z
116 Y
110 x 2
74
71 X
88 X
88 X
181
286
390
95
95
143
143
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
Propane P. C.S. = 50.37 MJ/kg
Butane P. C.S. = 49.47 MJ/kg
Methane P.C.S. = 37.78 MJ/kg
Element
Heat Input
230-240V ~
TWIN GRILL
L/H OVEN
R/H OVEN
WARMING DRAWER
Max Input
2.50 kW
1.60 kW
1.80 kW
0.15 kW
6.00-6.80 kW