Installation
! Before operating your new appliance please read this instruction booklet
carefully. It contains important information for safe use, installation and care
of the appliance.
! Please keep these operating instructions for future reference. Pass them on
to possible new owners of the appliance.
The hobs have the following technical characteristics:
-Category I3+/I3P
- Class 1: all models whose edges are higher than/equal to 73,5 mm (see
following page, detail H3).
- Class 3: all models whose edges are lower than/equal to 73,5 mm (see
following page, detail H1 and H2).
Positioning
! Keep packaging material out of the reach of children. It can become a choking
or suffocation hazard (see Precautions and tips).
! The appliance must be installed by a qualied professional according to the
instructions provided. Incorrect installation may cause harm to people and
animals or may damage property.
! This unit may be installed and used only in permanently ventilated rooms
in accordance with current national regulations. The following requirements
must be observed:
The room must be equipped with an air extraction system that expels
any combustion fumes. This may consist of a hood or an electric fan that
automatically starts each time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the Outside
The room must also allow proper air circulation, as air is needed for
combustion to occur normally. The ow of air must not be less than 2 m
3
/h
per kW of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an
inner cross section of at least 100 cm
2
; the
opening must not be vulnerable to any type
of blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms
tted with air circulation tubes as described
above. However, these rooms must not be
communal rooms, bedrooms or rooms that
may present a re hazard.
Liquid petroleum gas sinks to the oor as it is heavier than air. Therefore,
rooms containing LPG cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored in rooms or
A
Examples of
ventilation holes
for comburant air.
Enlarging the ventilation slot
between window and floor.
Adjacent
Room
Room to be
Vented
storage areas that are below ground level (cellars, etc.). It is advisable to
keep only the cylinder being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens, replaces, stoves,
etc. ) which could raise the temperature of the cylinder above 50°C.
Fitting the appliance
The following precautions must be taken when installing the hob:
Kitchen cabinets adjacent to the appliance and higher than the worktop
must be situated from the edge of the rack min. 22mm at the side and
65mm at the back (see diagram).
If the hob is installed beneath a wall cabinet, the latter must be situated
min. 650mm from the upper edge of the hob (see diagram).
Hoods must be installed according to their relative installation instruction
manuals and at a minimum distance of 650 mm from the hob.
Place the wall cabinets adjacent to the hood
at a minimum height of 420 mm from the hob
(see gure).
Installation
Make sure you take all the necessary precautions to guarantee proper
installation in compliance with the applicable norms in force regarding accident-
prevention for electrical connection.For the correct operation of the appliance
when built into the cabinet, it is vital that the minimum distances illustrated in
Fig. 1 be respected. The hob features a type Y degree of protection against
overheating in compliance with norms.All surfaces adjacent to the cabinet and
the back panel should be made of materials resistant to a temperature of 65°C.
Min.
700
mm
50
mm
50
mm
Fig.1
600mm min.
420mm min.
650mm min.